Manuale Rosières RHP 675 PN Cappa da cucina

Hai bisogno di un manuale per il tuo Rosières RHP 675 PN Cappa da cucina? Di seguito è possibile visualizzare e scaricare gratuitamente il manuale in PDF in italiano. Questo prodotto attualmente ha 2 domande frequenti, 0 commenti e ha 0 voti. Se questo non è il manuale che desideri, contattaci.

Il tuo prodotto è difettoso e il manuale non fornisce alcuna soluzione? Rivolgiti a un Repair Café per il servizio di riparazione gratuita.

Manuale

Loading…

ENGLISH
DESCRIPTION
The hood may be in the filtering or the ducting version.
Filtering version (Fig. 1A or 1B): The hood aspirates the kitchen air saturated with fumes and odours, purifies it through
the grease filters and charcoal filter and returns clean air into the room. For constant efficiency, the charcoal filter must
be replaced periodically. The charcoal filter is not supplied.
Ducting version (Fig. 2): The hood aspirates the kitchen air saturated with fumes and odours, passes it through the
grease filters and expels it to the outside through an outlet pipe. With this version the charcoal filter is not required. Decide
from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend you install the hood
in the ducting version (if possible).
INSTALLATION
ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.
Remove the grease filters before proceeding with the assembly instructions. This will make the appliance easier to handle.
1. Removal of grease filters: Fig. 3: push the stop towards the rear of the appliance and turn the filter outwards.
INSTALLATION IN DUCTING VERSION: Before fixing, the outlet pipe for air evacuation to the outside must be installed.
Use an outlet pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified
material (according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes
in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside, follow all the other instructions
given on the “Warnings” sheet. Prepare the power supply within the telescopic chimney (for the electrical connection, follow
all the other instructions on the “Warnings” sheet).
2. Fixing to the wall: Draw a line on the wall in vertical line with your hob. Mark the first 2 holes to be drilled in the
wall, respecting the distances indicated in Fig. 4. Drill the 2 holes and fit the screw anchors provided. As already specified
on the “Warnings” sheet, bear in mind that the distance between the lower edge of the hood and the hob must be min.
650 mm. Fix the metal bracket (A) to the wall using the 2 holes just drilled (Fig. 5); the screws for fixing the bracket are
provided. Use the 2 cut-out triangles on the bracket to position it exactly along the vertical axis of the hood. Hang the
hood on the bracket (Fig. 6). Adjust the horizontal position moving the hood to the right or left so that it is aligned with
the wall units. If you also need to adjust the hood in height, operate on the adjusting screws (B) provided. When adjustment
has been completed, without removing the hood, mark the other 4 holes to be drilled (C) in the wall. Remove the hood
and drill the holes marked (8 mm diameter). Then use the 4 screw anchors and the 4 screws provided for final fixing.
3. Flange assembly: set the flange (E) over the motor and press slightly (Fig. 7).
4. Mount the plate of the electrical system (depending on the model) fixing it with 2 screws and 2 metal washers
(Fig. 8).
5. Fixing the telescopic flues:
5a - Adjust the width of the support bracket (D) of the telescopic flue by means of the screws (E) as shown in Fig.9; then,
by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned
along the axis with your hood.
5b - Connect the air outlet pipe to the air vent of the hood. - Use a flexible pipe and lock it to the air vent of the hood
with a metal hose clamp - Fig. 10 (pipe and clamp are not provided). - For exhaust hoods, turn the upper flue over so that
the air exhaust grid is in the lower section (Fig. 11).
5c - Plug in the hood. Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure
with the 2 screws (H) - Fig. 12.
INSTALLATION IN FILTERING VERSION: Prepare the power supply within the telescopic flues (for the electrical
connection, follow all the other instructions on the “Warnings” sheet).
Fixing to the wall: for fixing to the wall refer to the instructions for the ducting version (see points 2, 3, and 4), then
continue with the instructions below.
Fixing the telescopic flues: - Adjust the width of the support bracket (D) of the telescopic flue by means of the screws
(E) as shown in Fig. 9. - Then, by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in
such a way that it is positioned along the axis with your hood. - Mount the flange on the hood in correspondence to the
air outlet point (Fig. 13). – Take the air baffle and fit a flexible pipe to it (125 mm diameter) locking it with a metal hose
clamp (pipe and clamps are not provided). Fit the air baffle to the upper flue (Fig. 14) with 4 screws.
- Connect the flexible pipe to the flange on the air vent (Fig. 15). - Plug in the hood. Insert the extension flues setting
them on the hood; extend the upper flue to the ceiling and secure with the 2 screws H (Fig. 12). - Install the charcoal
filter fitting the two filter clips in their housings (Fig. 16) and turning the filter upward.
Scarica il manuale in italiano (PDF, 1.14 MB)
(Rispetta l’ambiente e stampa questo manuale solo se è veramente necessario)

Loading…

Valutazione

Facci sapere che cosa pensi della Rosières RHP 675 PN Cappa da cucina valutando il prodotto. Vuoi condividere la tua esperienze con questo prodotto o porre una domanda? Ti preghiamo di lasciare un commento al fondo della pagina.
Sei soddisfatto di Rosières RHP 675 PN Cappa da cucina?
No
Valuta per primo questo prodotto
0 voti

Partecipa alla conversazione su questo prodotto

Qui puoi condividere cosa pensi di Rosières RHP 675 PN Cappa da cucina. Se hai una domanda, leggi prima attentamente il manuale. La richiesta di un manuale può essere effettuata utilizzando il nostro modulo di contatto.

Maggiori informazioni su questo manuale

Comprendiamo che sia bello avere un manuale cartaceo per i tuoi Rosières RHP 675 PN Cappa da cucina. Puoi sempre scaricare il manuale dal nostro sito web e stamparlo tu stesso. Se desideri avere un manuale originale, ti consigliamo di contattare Rosieres. Potrebbero essere in grado di fornire un manuale originale. Stai cercando il manuale del tuo Rosières RHP 675 PN Cappa da cucina in un'altra lingua? Scegli la tua lingua preferita sulla nostra home page e cerca il numero del modello per vedere se è disponibile.

Specifiche

Marca Rosieres
Modello RHP 675 PN
Categoria Cappe da cucina
Tipo di file PDF
Dimensione del file 1.14 MB

Tutti i manuali per Rosières Cappe da cucina
Altri manuali di Cappe da cucina

Domande frequenti su Rosières RHP 675 PN Cappa da cucina

Il nostro team di supporto cerca informazioni utili sul prodotto e risposte alle domande più frequenti. Se trovi un’inesattezza nelle nostre domande frequenti, ti preghiamo di farcelo sapere utilizzando il nostro modulo di contatto.

Quale distanza deve esserci tra la mia cappa da cucina e il piano di cottura? Verificato

Questo può variare a seconda della marca, ma generalmente una cappa va posizionata almeno 65 cm sopra una cucina a gas e almeno 50 cm sopra una cucina elettrica o a induzione. Questo per migliorare la sicurezza antincendio.

È stato utile (1215) Per saperne di più

Che differenza c’è tra una cappa con o senza motore? Verificato

Le cappe a motore sono indicate dove l’aria deve essere trasportata direttamente all’esterno. Una cappa senza motore è adatta in caso di sistema di ventilazione centrale. Non collegare mai una cappa a motore a un sistema di ventilazione centrale!

È stato utile (636) Per saperne di più
Manuale Rosières RHP 675 PN Cappa da cucina

Prodotti correlati

Categorie correlate