Manuale Broan HI190I Cappa da cucina

Hai bisogno di un manuale per il tuo Broan HI190I Cappa da cucina? Di seguito è possibile visualizzare e scaricare gratuitamente il manuale in PDF in italiano. Questo prodotto ha attualmente 2 domande frequenti, 0 commenti e ha 1 voto con una valutazione media del prodotto di 100/100. Se questo non è il manuale che desideri, contattaci.

Il tuo prodotto è difettoso e il manuale non fornisce alcuna soluzione? Rivolgiti a un Repair Café per il servizio di riparazione gratuita.

Manuale

Loading…

ENGLISH
The appliance must be installed by a qualified person in compliance with the instructions provided.
Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
Only for hoods equipped with electronic control:
The 4th speed (intensive) is automatically lowered to 3rd speed after 5 minutes of operation to optimise energy consumption.
- If the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user, it will automatically
switch to OFF condition with all services switched off.
- The Buzzer emits a “beep” each time that a command is set from the keyboard or remote control (optional).
- In the event of interruption of power during the hood, if you restore the hood in the OFF state, then the engine must
be reactivate manually.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
DESCRIPTION
The hood may be installed in the filtering or the ducting version.
In the Filtering version the air and the kitchen fumes that are conveyed by the apparatus are depurated by
the charcoal filters and put back into the room through the small grilles of the ventilation flue (Fig. 1).
ATTENTION: When using the filtering version, a charcoal filters and an air baffle (Fig. 1A) must be used, which
placed at the top of the structure, allows the air to recycle back into the room.
In the Ducting version, cooking vapours and odours are conveyed straight outside by a disposal duct which
passes through the ceiling (Fig. 2).
INSTALLATION
ATTENTION: Three people are required for proper installation; the unit should be installed by a qualified
operator. Also follow carefully each step of the assembly instructions, and once installation has been
completed, make sure that the hood is firmly secured in place.
To facilitate installation, before starting remove the grease filters: press inward on the clamp at the handle and
pull the filter downward (Fig. 3).
For assembling it is essential to: – Prepare the electrical connection and the air exhaust pipe (CAUTION! For installation
reasons the pipe must absolutely be flexible) inside the telescopic flue so that they are sufficiently long to reach the lower
flue outlet (Fig. 4). – If your unit is installed in a ducting hood, prepare the air exhaust hole.
When installing ducting hoods, to achieve the best possible conditions use an air exhaust pipe that : is as short
as possible, has a minimum of curves (maximum angle: 90°), is made of a material that complies with the standards (which
vary from nation to nation) and is smooth on the inside. It is also advisable to avoid any drastic changes in pipe section
(diameter: 150 mm).
ASSEMBLING - Using the special drilling template, drill the holes for fixing to the ceiling on the vertical side of
your hob. Carefully observe all the indications for final positioning of the apparatus. Take into account that one of
the template axes must correspond to the axis of the hood controls. Fix the bracket to the ceiling using the screws
and screw anchors provided (Fig. 5). Be careful, because the position of the bracket determines the final position
of the apparatus.
Ducting version: Fix the upper flue to the bracket by means of the four screws provided (Fig. 6), with the grilles facing
down, then take the lower flue and insert it in the upper one (Fig. 7). Adjust the height of the flues with the eight retaining
screws (Fig. 7A) taking into account that the hood is 110 mm high and that the distance between the hood and the
hob must be at least 650 mm (Fig. 8).
Take the flange with the metal valve (Fig. 9H) and assemble it onto the opening of the hood for air venting, pressing slightly.
Now make the electrical connection A and connect the air exhaust pipe to the flange B holding the hood raised (Fig.10).
Lift the island and rest it against the lower flue, then fix the parts with the 10 screws provided (Fig. 11). At this point
the installation is complete and the grease filters can be remounted.
Filtering version: After fitting the bracket to the ceiling, install the baffle (Fig. 12) with the four screws “A”; fix the flange
“B” with a rotating movement. Arrange the power cable and the air exhaust pipe as shown in Figure 13. Repeat the
installation from the first point of the ducting version bearing in mind that the upper flue must have the grilles facing up.
CHARCOAL FILTER/S (A) - Fig. 16: one or more charcoal filters are required in the filtering version. If they are
not yet installed in the hood, fit them inside the grease filter (M). Charcoal filters are not required In the ducting version.
If they are already installed in the hood remove them together with the relative filter retainers.
Scarica il manuale in italiano (PDF, 0.52 MB)
(Rispetta l’ambiente e stampa questo manuale solo se è veramente necessario)

Loading…

Valutazione

Facci sapere che cosa pensi della Broan HI190I Cappa da cucina valutando il prodotto. Vuoi condividere la tua esperienze con questo prodotto o porre una domanda? Ti preghiamo di lasciare un commento al fondo della pagina.
Sei soddisfatto di Broan HI190I Cappa da cucina?
No
100%
0%
1 vota

Partecipa alla conversazione su questo prodotto

Qui puoi condividere cosa pensi di Broan HI190I Cappa da cucina. Se hai una domanda, leggi prima attentamente il manuale. La richiesta di un manuale può essere effettuata utilizzando il nostro modulo di contatto.

Maggiori informazioni su questo manuale

Comprendiamo che sia bello avere un manuale cartaceo per i tuoi Broan HI190I Cappa da cucina. Puoi sempre scaricare il manuale dal nostro sito web e stamparlo tu stesso. Se desideri avere un manuale originale, ti consigliamo di contattare Broan. Potrebbero essere in grado di fornire un manuale originale. Stai cercando il manuale del tuo Broan HI190I Cappa da cucina in un'altra lingua? Scegli la tua lingua preferita sulla nostra home page e cerca il numero del modello per vedere se è disponibile.

Specifiche

Marca Broan
Modello HI190I
Categoria Cappe da cucina
Tipo di file PDF
Dimensione del file 0.52 MB

Tutti i manuali per Broan Cappe da cucina
Altri manuali di Cappe da cucina

Domande frequenti su Broan HI190I Cappa da cucina

Il nostro team di supporto cerca informazioni utili sul prodotto e risposte alle domande più frequenti. Se trovi un’inesattezza nelle nostre domande frequenti, ti preghiamo di farcelo sapere utilizzando il nostro modulo di contatto.

Quale distanza deve esserci tra la mia cappa da cucina e il piano di cottura? Verificato

Questo può variare a seconda della marca, ma generalmente una cappa va posizionata almeno 65 cm sopra una cucina a gas e almeno 50 cm sopra una cucina elettrica o a induzione. Questo per migliorare la sicurezza antincendio.

È stato utile (1215) Per saperne di più

Che differenza c’è tra una cappa con o senza motore? Verificato

Le cappe a motore sono indicate dove l’aria deve essere trasportata direttamente all’esterno. Una cappa senza motore è adatta in caso di sistema di ventilazione centrale. Non collegare mai una cappa a motore a un sistema di ventilazione centrale!

È stato utile (636) Per saperne di più
Manuale Broan HI190I Cappa da cucina

Prodotti correlati

Categorie correlate